The Gas Valve Is the Last Thing to Check

In this concise instructional video, the speaker addresses new HVAC technicians and explains the proper diagnostic order for a furnace that is not producing heat. He emphasizes that the gas valve should be examined only after confirming that earlier steps in the furnace start‑up sequence have succeeded: the inducer motor must have established proper draft, the pressure switch must be closed, the igniter must reach its operating temperature, and the control board must have sent a 24 V signal to the valve. The speaker provides a quick checklist—verify igniter glow, pressure‑switch status, and 24 V at the valve terminals—before concluding that a non‑opening valve is the likely fault. The overall message is to follow the sequence methodically, using the gas valve as a last‑resort suspect, and to share this knowledge with others.